Braz. dent. j ; 26(3): 258-262, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-751869

ABSTRACT

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.


Considerando os valores relativamente pequenos utilizados em odontologia para os ensaios de carregamento verticais axiais, foi desenvolvido um dispositivo de aplicação de carga (DAC) para substituir a máquina de ensaios universal (EMIC). O objetivo deste estudo foi desenvolver um DAC e compará-lo com a EMIC por meio da utilização de carregamentos axiais e não-axiais. Num bloco de poliuretano foi inserido um implante hexágono externo, o qual foi conectado a um pilar protético esteticone. Sobre o pilar protético foi parafusada uma coifa plástica e um pilar cônico foi modelado em resina acrílica, que foi moldada para a obtenção de dez enceramentos iguais que foram fundidos em níquel cromo. Quatro extensômetros foram diametralmente colados ao redor do implante. Cada corpo de prova foi submetido a cargas axiais central (C) e lateral (L) de 30 kgf, em ambos os dispositivos: G1) DAC/C; G2) DAC/L; G3) EMIC/C; G4) EMIC/L. Os dados (µε) foram analisados estatisticamente pelos testes de ANOVA para medidas repetidas e de Tukey (p<0,05). Não houve diferença estatisticamente significante entre os dispositivos DAC e EMIC, independente do tipo de carga. A aplicação de carga não-axial (NA) determinou um aumento significante de tensões ao redor do implante. Foi concluído que o DAC é uma opção confiável, a qual induz microtensão em implantes de forma semelhante à EMIC.


Subject(s)
Dental Prosthesis , Dental Stress Analysis/instrumentation
2.
ImplantNews ; 9(6a): 88-93, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850998

ABSTRACT

O objetivo neste trabalho foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes autorrosqueáveis de hexágono externo, com dimensões de 3,75 mm x 13 mm, a uma distância de 7 mm, de centro a centro. Em outro bloco, a fixação do meio foi deslocada em 2 mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3 mm de cinta, foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados dez enceramentos para cada bloco (n = 10). A seguir, esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco, tangenciando a plataforma de cada fixação. Um carregamento de 30 kg durante dez segundos foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em µɛ) pelo aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (RM Anova) e teste de Tukey (p < 0,05). Como conclusão da análise dos resultados obtidos, pudemos observar que não houve diferença entre as configurações linear e compensada; havendo diferença estatisticamente significante para os locais de carregamento.


The aim of this study was to evaluate through strain gauge methods the load distribution around dental implants regarding different sites and configurations (linear and offset). Three cylindrical implants with external hexagon (3.75 mm x 13mm) connection were fixed parallel in a polyurethane model with 7 mm between their centers in a linear configuration. In another block, the middle implant was positioned 2 mm offset. After, micro-unit abutments (3 mm of metallic collar height) were tightened. Ten wax patterns were created for each block (n = 10) and cast in Cobalt-Chromium alloy. Four strain gauges were positioned on the upper surface of each polyurethane model around the implants. A 30 kg axial load was applied for 10 seconds in five positions (A, B, C, D, and E), with three repeated measurements for data aquisition (in µɛ) by the multichannel bridge machine. Data were submitted to Anova and Tukey´s test (p < 0.05). It was concluded that: 1) no difference was seen between the linear and offset configurations and 2) there was statistical significance for different loading sites


Subject(s)
Dental Implants , Dental Prosthesis
3.
ImplantNews ; 9(4): 571-575, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-729983

ABSTRACT

Este estudo avaliou, in vitro, por meio da extensometria, as diferentes deformações ao redor de um implante de hexágono externo após a aplicação de carga em três pontos distintos sobre coroas unitárias, fixado em um bloco de poliuretano. Quatro extensômetros foram colados, diametralmente opostos e tangentes ao implante, na superfície do bloco para quantificar a microdeformação peri-implantar no momento da aplicação da carga. Um pilar protético esteticone foi conectado ao implante com torque de 20 Ncm. Sobre o pilar foi parafusado, a cada sessão de teste, um padrão fundido em liga de Co-Cr (n = 10) com torque de 10 Ncm, que recebeu o carregamento. A carga de 30 kg foi aplicada sobre três pontos predeterminados e os dados de microdeformação registrados com auxílio de um condicionador de sinais elétricos e do software Strain-Smart. Os resultados obtidos foram submetidos à análise estatística utilizando a Análise de Variância (Anova) e o teste de comparação múltipla de Tukey (5%). Os valores médios da microdeformação para as cargas foram: ponto A = 307,6 ponto B = 302,3 e ponto C = 669,5. Pôde-se concluir que os fatores de deslocamento centrífugo do ponto de aplicação de carga interferem significativamente na microdeformação gerada ao redor do implante.


This in vitro study evaluated microstrain levels around a single-tooth, external hexagon dental implant crown. An Estheticone abutment was connected to the implant with 20 Ncm torque, and a single crown cast in Co-Cr alloy (n=10) delivered with 10Ncm. Four strain gauges were bonded, diametrically opposed and tangential to the implant, on the surface of the polyurethane block. After, a 30Kg-load was applied at three different points (A, B, and C). Microstrain (µε) values were recorded with the aid of an electric signal conditioner and the Strain-Smart software. Statistical analyses were performed with Anova and multiple comparison Tukey´s test (5% significance level). Mean deformation values were: point A = 307.6 µε, point B = 302.3 µε, and point C = 669.5 µε. It was concluded that centrifugal displacement of the loading application point interferes significantly with microstrain levels around the dental implant.


Subject(s)
Dental Prosthesis, Implant-Supported
4.
J. appl. oral sci ; 19(6): 610-615, Nov.-Dec. 2011. ilus, tab
Article in English | LILACS | ID: lil-610875

ABSTRACT

OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. RESULTS: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 µε) and point D the highest (442.77 µε). No significant difference was found for the cylinder type (p=0.748). CONCLUSIONS: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.


Subject(s)
Humans , Dental Implants , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Analysis of Variance , Chromium Alloys/chemistry , Dental Abutments , Dental Prosthesis Design , Materials Testing , Stress, Mechanical , Surface Properties , Torque
5.
RPG, Rev. Pós-Grad ; 16(4): 201-206, out.-dez. 2009. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-855249

ABSTRACT

O objetivo do estudo foi avaliar a resistência à tração de pino de fibra de vidro cimentado com três diferentes cimentos. Trinta dentes bovinos foram selecionados. Os comprimentos dos espécimes foram padronizados em 16 mm. Os espécimes foram divididos em três grupos, de acordo com os cimentos, os quais foram utilizados seguindo as instruções dos fabricantes: G1, Panavia F; G2, Ketac Cem; G3, RelyX Unicem. Os espécimes foram submetidos ao teste de tração em uma máquina de teste universal com velocidade de 1 mm/min. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (µ = 0,05). O G2 (37,25 ± 10,84 Kgf) demonstrou maior resistência ao teste de tração (p < 0,0034) quando comparado ao G3 (24,24 ± 6,47 Kgf) e G1 (23,45 ± 9,78 Kgf) os quais não diferiram estatisticamente entre si. A análise dos espécimes demonstrou que todas as falhas do G1 e G3 ocorreram na interface cimento/dentina radicular, enquanto todas as falhas do G2 ocorreram na interface pino/cimento. Concluiu-se que o cimento de ionômero de vidro Ketac Cem produziu maior resistência à tração dos pinos de fibra de vidro, quando comparado aos cimentos resinosos RelyX Unicem e Panavia F. A hipótese nula foi aceita (p < 0,0034)


Subject(s)
Cattle , Dental Cements , Dental Pins , Resin Cements , Tensile Strength , Dental Pulp Cavity , Dentin , Glass Ionomer Cements
6.
São José dos Campos; s.n; 2011. 107 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866972

ABSTRACT

O objetivo neste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais e não-axiais em próteses parciais fixas de 3 elementos implanto-suportadas, variando o posicionamento dos implantes e os pontos de aplicação de carga. Dois blocos de poliuretano receberam três implantes com conexão hexágono interno, no posicionamento linear e compensado. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Coifas plásticas foram parafusadas sobre os pilares, que receberam enceramentos padronizados, os quais foram fundidos em liga de Co-Cr (n=10). Quatro extensômetros (SG) foram colados na superfície do bloco, SG 01 mesialmente ao implante 1, SG 02 e SG03 mesialmente e distalmente ao implante 2, respectivamente, e SG 04 distalmente ao implante 3, tangenciando os implantes visando mensurar a micro deformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm e a seguir foi realizada a aplicação de carga axial de 30 kgf em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto de aplicação de carga E (não-axial) gerou a maior micro deformação (327,67με) e o ponto de aplicação de carga A (axial) a menor micro deformação (208,93με). Com relação ao posicionamento dos implantes não foi observada diferença estatisticamente significante (p=0,856). Concluiu-se que o posicionamento compensado dos implantes não reduziu a magnitude de micro deformação peri-implantar durante a aplicação de cargas axiais e não-axiais e que a localização da aplicação de carga influenciou a magnitude desta micro deformação


The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading of implant-supported fixed partial prostheses, varying implant placement configurations and the loading points. Material and methods: Three internal hexagon implants were embedded in the center of each polyurethane block in straight and off-set placement. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=10). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and axial and non-axial load of 30 kgf was applied at five predetermined points. The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey’s test, with a conventional level of significance of p<0.05. The results showed a statistically significant difference for the loading point (p=0.0001), with point E (non-axial) generating the highest microdeformation (327.67 με) and point A (axial) the smallest (208.93 με). No statistically significant difference was found for implant placement configuration (p=0.856). It was concluded that offset implant placement did not reduce the magnitude of microstrain around implants under axial and non axial loading conditions and loading location influenced this magnitude


Subject(s)
Dental Implants , Dental Prosthesis , Dental Prosthesis, Implant-Supported
7.
Braz. dent. sci ; 14(3/4): 4-11, 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-727403

ABSTRACT

Este estudo avaliou o efeito do jateamento de óxido de alumínio (Al2O3) na resistência de união de uma liga de ouro e uma de cobalto-cromo à uma cerâmica, submetidos ao ensaio de flexão de três pontos (ISO 9693). Sessenta barras metálicas (25x3x0,5mm) foram divididas de acordo com a liga: Au e Co-Cr; e o tratamento de superfície do metal: ponta de tungstênio (W), jateamento de Al3O2 (JAT) a 10mm de distância e jateamento de Al3O2 a 20mm de distância, formando 6 grupos: G1.1- Au + W; G1.2 - Au + W + JAT a 10mm; G1.3 - Au + W + JAT a 20mm; G2.1 – Co-Cr + W; G2.2 - Co-Cr + W + JAT a 10mm; G2.3 - Co-Cr + W + JAT a 20mm. A cerâmica de cobertura foi coccionada sobre a área central de acordo com as recomendações do fabricante. Os espécimes foram submetidos ao teste de flexão de três pontos. Foi realizada análise de variância a 2 fatores e teste de Tukey (α=0,05). Os modos de falhas foram analisados, qualitativamente, em lupa estereomicroscópica. Os valores médios de resistência de união e desvio-padrão (em MPa) foram: G1.1: 42,36±6,45; G1.2: 48,75±3,80; G1.3: 50,55±5,49; G2.1: 40,18±8,05; G2.2: 50,51±9,71; G2.3: 49,71±6,53. Observou-se que houve diferença estatisticamente significante para o fator tratamento de superfície (p=0,002), sendo que os grupos tratados com jateamento de Al3O2 a 10mm e 20mm de distância produziram valores de resistência flexural similares entre si e significantemente maiores que aqueles tratados com ponta de tungstênio. O modo de falha predominante foi adesiva na interface metal/cerâmica, sem a presença de cerâmica na superfície do metal para o grupo G1.1 e G2.1 e exclusivamente mista na interface metal/cerâmica, com presença de opaco e cerâmica de corpo na superfície da metal para os demais grupos. Concluiu-se que o tipo de liga não interferiu nos valores de resistência de união e o jateamento com Al3O2 melhorou significantemente os valores de resistência de união entre a cerâmica e as ligas estudadas


The purpose of this study was to evaluate the effect of airborne particle abrasion on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr) and gold alloy. Sixty metallic frameworks were made (25x3x0.5 mm) according ISO 9693 and were divided according to the alloy (gold alloy and Co-Cr alloy), and the surface treatment (tungsten drill (W), air-particle abrasion with Al3O2 (APA) from a distance of 10mm and air-particle abrasion with Al3O2 from a distance of 20mm), making a total of six groups: G1.1 – Au + W; G1.2 - Au + W + APA; G1.3 - Au + W + APA 20mm; G2.1 – Co-Cr + W; G2.2 - Co-Cr + W + APA 10mm; G2.3 - Co-Cr + W + APA 20mm. At the central area of the frameworks (8x3 mm), the opaque ceramic (Opaque, Vita Zahnfabrick) was applied and the glass ceramic (Vita VM13, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). A flexural strength test was performed in a universal testing machine. The data were analyzed using 2 way-ANOVA and Tukey´s test (α = 0.05). The failure types were analyzed using a stereomicroscope (30X). The means and standard deviations of the flexural bond strength were (MPa): G1.1: 42,36±6,45; G1.2: 48,75±3,80; G1.3: 50,55±5,49; G2.1: 40,18±8,05; G2.2: 50,51±9,71; G2.3: 49,71±6,53. There was a significant difference for surface treatment factor (p=0,002). The mean flexural strength values for APA 10mm and APA 20mm groups were similar and significantly higher than tungsten drill groups. The failure type was most adhesively in the metal/ceramic interface for the groups G1.1 and G2.1, and exclusively mixed in the metal/ceramic interface, presenting opaque and dentin ceramic in the metal surface, for the others groups. It was concluded that the type of alloy did not affect the bond strenght values and the air-paricle abrasion with Al3O2 improved the flexural bond strenght between ceramics and alloys used.


Subject(s)
Air Abrasion, Dental , Ceramics , Chromium Alloys , Dental Materials , Gold Alloys
8.
ImplantNews ; 8(3): 363-369, 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-599229

ABSTRACT

Com a crescente busca pela estética, uma integração final invisível entre tecido, implante e coroa tem sido um dos principais desafios da Implantodontia atual. Uma alternativa recente é a utilização do pilar protético de zircônia, que permite ao cirurgião-dentista realizar reabilitações protéticas totalmente cerâmicas, pilar protético e coroa, combinando fatores como resistência, excelente estética e satisfação do paciente. Este artigo relata um caso clínico na região anterossuperior, envolvendo o dente 22, no qual uma fratura radicular inviabilizou a manutenção do dente na arcada dentária. O tratamento reabilitador consistiu na realização da cirurgia de extração do dente 22 e de colocação de implante imediato, seguido de instalação de coroa provisória imediata na região. Em seguida, o tratamento protético foi realizado por meio da confecção de coroa unitária implantossuportada sobre pilar de zircônia, utilizando-se o sistema In-ceram Alumina. Clinicamente, observou-se que o uso do pilar de zircônia associado a coroa também livre de metal permitiu ao cirurgião-dentista alcançar o resultado estético e funcional desejado, com perfeita integração entre tecido gengival e coroa, além de adequada performance mecânica. Além disso, pode-se constatar que em condições clínicas favoráveis a instalação de implante imediato, seguida de instalação de coroa provisória imediata, representa uma opção de tratamento viável.


With the increasing quest for aesthetics, a perfect integration between tissue, dental implant, and restorations have been the challenge of current Implant Dentistry. An alternative is the use of high-strength ceramic abutments, such as zirconia, which combines factors such as resistance and aesthetics. This article reports a clinical case in where an anterior tooth loss was reestablished with an immediate implant, followed by immediate temporary implant-supported zirconia abutment, using the In-Ceram alumina system. The authors observed that treatment with zirconia abutment provided the desired functional and aesthetic outcomes.


Subject(s)
Humans , Female , Adult , Ceramics , Dental Prosthesis , Esthetics, Dental , Immediate Dental Implant Loading , Dental Implants
9.
J. appl. oral sci ; 18(3): 225-230, May-June 2010. ilus
Article in English | LILACS | ID: lil-557084

ABSTRACT

OBJECTIVE: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different microstrains and the type of copings would produce similar microstrains after prosthetic screws had been tightened onto microunit abutments. MATERIALS AND METHODS: Three dental implants with external (EH) and internal (IH) hexagonal configurations were inserted into two polyurethane blocks. Microunit abutments were screwed onto their respective implant groups, applying a torque of 20 Ncm. Machined Co-Cr copings (M) and plastic prosthetic copings (P) were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in Co-Cr alloy (n=5), forming four groups: G1) EH/M; G2) EH/P; G3) IH/M and G4) IH/P. Four SGs were bonded onto the surface of the block tangentially to the implants, SG 1 mesially to implant 1, SG 2 and SG 3 mesially and distally to implant 2, respectively, and SG 4 distally to implant 3. The superstructure's occlusal screws were tightened onto microunit abutments with 10 Ncm torque using a manual torque driver. The magnitude of microstrain on each SG was recorded in units of microstrain (µε). The data were analyzed statistically by ANOVA and Tukey's test (p<0.05). RESULTS: Microstrain values of each group were: G1= 338.1±223.0 µε; G2= 363.9±190.9 µε; G3= 415.1±53.5 IE; G4= 363.9±190.9 µε. No statistically signifcant difference was found between EH and IH, regardless of the type of copings (p>0.05). The hypotheses were partially accepted. CONCLUSIONS: It was concluded that the type of hexagonal connection and coping presented similar mechanical behavior under tightening conditions.


Subject(s)
Humans , Dental Abutments , Dental Implants , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Dental Materials/chemistry , Chromium Alloys/chemistry , Materials Testing , Plastics/chemistry , Signal Processing, Computer-Assisted , Stress, Mechanical , Surface Properties , Torque , Transducers
10.
Braz. j. oral sci ; 9(1): 11-15, Jan.-Mar. 2010. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-578039

ABSTRACT

Aim: To evaluate the occurrence of microstrain around morse taper implants in straight configuration under axial load in a cast monoblock framework. Methods: Three implants were inserted in a polyurethane block and microunit abutments were installed on the implants with 20 Ncm torque. Plastic and machined copings were adapted on the preset waxing to fabricate the framework (n=5). Four strain gauges were attached on the upper surface of the block and then each framework was tightened on the abutments and a vertical load of 30 kg was applied to five points of the framework. Results: The data obtained in the strain gauge analysis were subjected to twoway ANOVA and Tukey’s test (=0.05). There was statistically significant difference (p=0.0222) for the factor application point and the mean microstrain values were: application point B 402,04µ, point A 401.21µ, point E 390.44µ, point D 341.76µand point C 309.19 µ. Conclusions: There was no microstrain difference between plastic and machined copings during axial loading. Difference in the application point was observed, but remained within bone physiological limits.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Denture, Partial, Fixed , Analysis of Variance , Dental Abutments , Materials Testing , Stress, Mechanical
11.
ImplantNews ; 7(3): 323-329, 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-563036

ABSTRACT

A crescente exigência estética tem levado ao constante desenvolvimento dos pilares protéticos na Implantodontia. O pilar protético de Zircônia permite ao cirurgião-dentista indicar ao paciente reabilitações protéticas totalmente cerâmicas, pilar protético e coroa, o que pode propiciar ótimo resultado estético e alto nível de satisfação do paciente. Este artigo relata uma abordagem multidisciplinar para o tratamento de um caso clínico na região ântero-superior, envolvendo os dentes 11, 12, 13, 14 e 15, no qual houve perdas dentárias dos elementos 11 e 14 em consequência de um trauma. O tratamento restaurador consistiu na realização de cirurgia de implante imediato seguido de coroa provisória imediata na região do dente 11, enquanto que o tratamento protético foi realizado por meio da confecção de coroa unitária implantossuportada sobre pilar de zircônia, confecção de coroa unitária no dente 12 e prótese parcial fixa de três elementos dos dentes 13 ao 15, utilizando-se o sistema In-Ceram Zircônia. Observou-se clinicamente que o uso do pilar de Zircônia e de próteses livres de metal permitiu alcançar excelente resultado estético e adequada performance mecânica. Verificou-se também que quando as condições clínicas são favoráveis, a estratégia de instalação de implante imediato, seguido de coroa provisória imediata, é uma opção viável.


The increase of aesthetic requirements has led to the constant development of new abutments on Implantology. The zirconia abutment allows clinicians to provide patients with an all-ceramic restorative system (abutment and crown) which can generate excellent aesthetic results and high level of patient satisfaction. This article reports a multidisciplinary approach to the treatment of a clinical case in the anterior maxillary region involving teeth 11, 12, 13, 14, and 15, where elements 11 and 14 were lost due to trauma. The restorative treatment consisted of immediate implant placement and immediate temporary crown in the region of tooth 11, while the prosthetic treatment was performed through the construction of single crown on implant-supported zirconia abutment, a single crown on tooth 12 and a 3-element fixed partial denture on teeth 13 to 15, using the In-Ceram Zirconia system. It was clinically observed that the use of zirconia abutment and all-ceramic prostheses achieved excellent aesthetic result and adequate mechanical performance. Also, it was verified that in cases where clinical conditions are favorable, the strategy of immediate implant placement and provisionalization is a viable option.


Subject(s)
Humans , Male , Adult , Dental Implants, Single-Tooth , Esthetics, Dental
12.
ImplantNews ; 7(4): 483-487, 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-564684

ABSTRACT

A exigência estética em Odontologia tem levado ao desenvolvimento de novos materiais. Os pilares cerâmicos surgem como uma alternativa viável nas reabilitações protéticas em regiões onde a estética é primordial. Este artigo tem por finalidade revisar considerações relevantes na propriedades mecânicas e biológicas dos pilares cerâmicos.


Aesthetic demands in dentistry have turned into the development of newer materials. Ceramic abutments appear as a viable alternative for prosthetic rehabilitations in esthetic regions where this is the primary concern. The objective of this article is to review some relevant aspects about ceramic abutment´s mechanical and biological properties.


Subject(s)
Esthetics, Dental , Dental Implants
13.
Braz. dent. sci ; 12(4): 25-33, out.-dez. 2009. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-587933

ABSTRACT

Este estudo avaliou a influência da temperatura de queima da camada de opaco na resistência de união entre uma liga de cobalto-cromo e uma cerâmica, após serem submetidos ao ensaio de flexão de três pontos. Considera-se a hipótese: o aumento da temperatura de queima do opaco melhora a resistência flexural da cerâmica aplicada sobre o metal. Barras metálicas (25x3x0,5mm) (n=30) foram fundidas em Co-Cr e as áreas centrais das barras (8x3mm) foram jateadas com partículas de óxido de alumínio de 150μm e divididas em 3 grupos de acordo com a temperatura de queima da camada de opaco (n=10): G1 (grupo controle) – 900°C; G2 – 950°C e G3 – 1000°C. As cerâmicas opaca e de corpo (Vita Omega 900) foram queimadas sobre a área central. Os espécimes foram mantidos em água destilada à 37° C durante 24 horas e a seguir foram submetidos ao teste de flexão de três pontos. Após o teste, os tipos de falhas foram classificados. Os dados obtidos foram analisados estatisticamente (Kruskal-Wallis 1 e teste de Dunn , μ=0,05). A diferença dos valores médios de resistência flexural foi estatisticamente significante (p=0,004), sendo que os grupos G2- 19,84±4,24N e G3- 22,43±5,94N exibiram valores de resistência flexural maiores que o grupo G1-12,525±1,08N. Concluiu-se que o aumento da temperatura de queima da camada de opaco melhorou significantemente os valores de resistência flexural. O modo de falha predominante foi adesiva na interface metal/cerâmica para o grupo G1 e exclusivamente coesiva na zona interfacial camada de opaco/Co-Cr com presença de cerâmica na superfície dos grupos G2 e G3.


This study evaluated the opaque layer firing temperature on the flexural strength of a ceramic fused to commercial cobaltchromiumalloy (Co-Cr). The hypotheses were that opaque layer temperature increasing get higher the metal/ceramicbond strength. Metallic frameworks (25x3x0.5 mm) (n=30) were cast in Co-Cr and airborne particle abraded with 150μm aluminum oxide at the central area of the frameworks (8x3 mm) and after divided into three groups, according toopaque layer firing temperature (n=10): G1 (control) – 900°C; G2- 950°C and G3- 1000°C. Opaque ceramic were appliedand the glass ceramic (Vita Omega 900, Vita Zahnfabrick, Bad Sãckingen, Germany) was fired onto them (thickness:1 mm). The specimens were kept in distilled water at 37ºC for 24 hours, after that it were submitted to three pointsflexural strenght test. After the test, failure types were noted. The data were analyzed using 1 way Kruskal-Wallis andDunn test (5%). The difference in mean flexure strength values were statistically significant (p=0,004). The groups G2-19,84±4,24N and G3- 22,43±5,94N presented higher flexure strength values than G1- 12,525±1,08N. It was concludedthat the opaque layer temperature increasing improved the flexure bond strength values significantly. The failure typepredominant was adhesive at metal/ceramic interface for group G1 sample and exclusively cohesive at the opaqueceramic/Co-Cr interfacial zone with presence of ceramic on the metal surface for groups G2 and G3.


Subject(s)
Ceramics , Metal Ceramic Alloys , Chromium Alloys , Dental Materials
14.
J. appl. oral sci ; 14(3): 213-218, May-June 2006. ilus, tab
Article in English | LILACS, BBO | ID: biblio-873216

ABSTRACT

O propósito deste estudo foi avaliar a reparação óssea ao redor de implantes de superfície porosa comparados com implantes de superfície rugosa, ambos confeccionados de titânio puro grau 2 por meio da técnica de metalurgia do pó. Os implantes foram inseridos em tíbias de coelhos. Foram utilizados neste estudo 7 coelhos machos, sendo que cada um recebeu 3 implantes de superfície porosa na tíbia esquerda e 3 implantes de superfície rugosa na tíbia direita. Os animais foram sacrificados 4 semanas após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica e histomorfométrica, visando analisar a neoformação óssea na interface osso-implante. As médias ( por cento) obtidas na análise histomorfométrica foram avaliadas por meio do teste estatístico t-student de amostras pareadas com nível de significância de 5 por cento. Os resultados da análise histológica mostraram que a osseointegração foi obtida nos dois tipos de implantes com similar qualidade de tecido ósseo. Na análise histomorfométrica, verificaram-se médias de neoformação óssea na interface osso-implante de 79,69 por cento ± 1,00 e 65,05 ± 1,23 para os implantes de superfície porosa e rugosa, respectivamente, e foi observada diferença estatisticamente significante entre os dois tipos de implantes com relação à quantidade de neoformação óssea. Concluiu-se que os implantes de superfície porosa contribuíram para a osseointegração devido à sua maior superfície de contato na interface osso-implante


Subject(s)
Animals , Rabbits , Biocompatible Materials , Materials Testing , Osseointegration , Titanium , Hardness Tests , Porosity , Prostheses and Implants , Surface Properties
15.
J. appl. oral sci ; 14(3): 213-218, May-June 2006. ilus, tab
Article in English | LILACS, BBO | ID: lil-448197

ABSTRACT

The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means ( percent) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5 percent significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00 percent and 65.05 ± 1.23 percent for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.


O propósito deste estudo foi avaliar a reparação óssea ao redor de implantes de superfície porosa comparados com implantes de superfície rugosa, ambos confeccionados de titânio puro grau 2 por meio da técnica de metalurgia do pó. Os implantes foram inseridos em tíbias de coelhos. Foram utilizados neste estudo 7 coelhos machos, sendo que cada um recebeu 3 implantes de superfície porosa na tíbia esquerda e 3 implantes de superfície rugosa na tíbia direita. Os animais foram sacrificados 4 semanas após a cirurgia e os fragmentos das tíbias contendo os implantes foram submetidos à análise histológica e histomorfométrica, visando analisar a neoformação óssea na interface osso-implante. As médias ( por cento) obtidas na análise histomorfométrica foram avaliadas por meio do teste estatístico t-student de amostras pareadas com nível de significância de 5 por cento. Os resultados da análise histológica mostraram que a osseointegração foi obtida nos dois tipos de implantes com similar qualidade de tecido ósseo. Na análise histomorfométrica, verificaram-se médias de neoformação óssea na interface osso-implante de 79,69 por cento ± 1,00 e 65,05 ± 1,23 para os implantes de superfície porosa e rugosa, respectivamente, e foi observada diferença estatisticamente significante entre os dois tipos de implantes com relação à quantidade de neoformação óssea. Concluiu-se que os implantes de superfície porosa contribuíram para a osseointegração devido à sua maior superfície de contato na interface osso-implante.


Subject(s)
Animals , Rabbits , Biocompatible Materials , Materials Testing , Osseointegration , Titanium , Hardness Tests , Porosity , Prostheses and Implants , Surface Properties